About 197,000 results
Open links in new tab
  1. Dwelling Unit, Receptacle spacing Requirement | Information by ...

    Mar 18, 2020 · If I where to put a receptacle in the next 2 feet, after the cabinet, I would satisfy the requirement of having a receptacle within a 6 foot reach. (210.52a1) ??? You're asking whether the …

  2. Dwelling kitchen receptacles required - 210.52 (A) (2) (1) and 210.52 ...

    Mar 8, 2022 · As a receptacle can be up to 5-1/2 feet above the floor and still serve the wall space, is there an issue? The countertop receptacles can serve the wall space. And since the countertop …

  3. Receptacle in a shallow box? | Information by Electrical Professionals ...

    Nov 23, 2020 · Quick question: Can a GFI receptacle be installed in a 1-1/4" deep box? Or perhaps a regular receptacle that is down stream of a GFI?

  4. Receptacle Termination & Wire Sizes | Information by Electrical ...

    May 2, 2007 · What is the largest size wire that can safely land on a receptacle termination? We normally use #12s everywhere, #10s for long distance runs but will #8s work? Is there some UL …

  5. NEC 210.52 (E) Outdoor outlets | Information by Electrical ...

    Aug 23, 2021 · The receptacle outlet shall not be located more than 6.5 feet above the balcony, deck, or porch walking surface. If there is a screened-in lanai (aluminum structure with insect screening) …

  6. 50-Amp EV Receptacle | Information by Electrical Professionals for ...

    Apr 6, 2025 · When did they start making 50-Amp Receptacles listed specifically for EV charging? & Are they now required per NEC? Thanks in advance!

  7. Hallway receptacles | Information by Electrical Professionals for ...

    Feb 13, 2020 · I agree with Dennis in the 2008 NEC for hallways less than 10' no receptacle required, more than 10' one required. And it doesn't matter if one side of your hallway has doors and the other …

  8. Single Receptacles | Information by Electrical Professionals for ...

    Mar 23, 2007 · single receptacle single receptacle Hi: The code refers to single receptacles at 210.21 (B) (1); 430.81 (B) and at 630.11 by a quick search. Also see definition of receptacle at Article 100. …

  9. Kitchen Counter Receptacle | Information by Electrical Professionals ...

    Jun 8, 2024 · I have a Kitchen Countertop and Work Surface according to 210.52(C) that is 24-inches wide but has a cabinet that comes right down onto the countertop thereby leaving only 9-inches of …

  10. Use of outlet as a disconnecting mean | Information by Electrical ...

    Oct 11, 2023 · Does the receptacle have a means to accept a locking device that remains in place? Can you add a lockout at the panel? Please review definition of disconnecting means.